ATMOS S 61 CORIAN ®
- Manufacturer
- ATMOS
- Category
- Medical clinics, Medical furniture
- Application area
- ENT medicine
Treatment unit for increased infection control requirements
Description
ATMOS S 61 CORIAN ® Unbeatable infection control and design versatility While developing its ATMOS S 61 CORIAN ® treatment unit, ATMOS aimed to provide ENT doctors with a solution that easily meets the infection control requirements stipulated in German regulations on preventing infection. To this end, ATMOS relied on a special material called CORIAN ® . This exceptionally robust material has a nonporous surface to ensure maximum infection control. Its almost unlimited range of design options makes it perfect for even the most discerning customers. Applications ENT outpatient department ENT examination room ENT practice Space concept Innovative concept for spatial separation No cross-contamination Strict spatial separation of clean and used instruments Compliance with infection control requirements The answer to increased infection control requirements ATMOS relied on a special material when developing its new treatment units: CORIAN ® . The hygienic properties of CORIAN ® reduce the risk of cross-contaminations and the spread of germs to a minimum. Find out more about CORIAN ® New material CORIAN ® Individual design options Wide range of color options ATMOS standard color When it comes to color design, our treatment units are available straight from the factory in one trendy color: Glacier White. Would you like something special? You can also choose from a wide range of special CORIAN ® color options, making your ENT treatment unit the perfect match for your practice’s interior design. CORIAN ® Color Selector Instrument management Drawers without handles The innovative Servo-Drive® system allows you to open drawers easily by tapping them gently with your knee, the back of your hand, or your elbow. For you this means: Effective protection of instruments against dust and contamination Low-vibration opening and closing to protect sensitive instruments Versatility within minimum space The ATMOS S 61 CORIAN ® treatment unit combines all the important treatment modules even in the smallest space. All modules are durable, easy to service and quiet, making your work easy and pleasant. One special highlight of this treatment unit: all functions start automatically when the handles are removed from their holders. Basis element Workstation Medication sprayer The one-handed operation prevents cross-contamination and makes it easy to change sprayers. The medication sprayers are available in the following versions: Medication sprayer with straight sprayer nozzle Medication sprayer with extendible nozzle Powder sprayer Automatic activation All functions of the ENT treatment unit start automatically when the handles are removed from their holders and can be operated with one hand. The most important treatment modules are combined in a compact space. Hose rinsing system The easily accessible rinsing canister prevents the suction system from becoming clogged. For uninterrupted work, the canister is available with an optional automatic filling feature. Ear irrigation system All water-bearing parts are autoclavable and therefore particularly easy to reprocess. A distinction can be made between the following options: Self-contained ear irrigation with compressed air (500 ml per irrigation) Uninterrupted ear irrigation with water connection (Hygrotherm 37 °C or Variotherm (nystagmus stimulation) 20–44 °C) Suction systems The suction systems can be divided into two suction capacity classes: Basic (40 l/min) Professional (55 l/min.), extremely quiet Secretion canister system The automatic canister emptying feature ensures uninterrupted work. The ATMOS Direct Docking System makes it easy to change secretion canisters — error-free. The secretion canister system is easily accessible from the front in the service compartment. Disposable canister systems It is possible to use disposable secretion hoses and canisters from other manufacturers: Serres ® Receptal ® other manufacturers on request Quick mirror heater To prevent the mirrors from fogging up, they can be preheated to body temperature.
Specifications
| Weight | 300 kg |
|---|---|
| Suction capacity | 55 l/min. |
| Pressure | 2 bar |
Variants
| 530.0300.0 | ATMOS S 61 CORIAN ® |
|---|---|
| 532.0800.0 | ATMOS S 61 CORIAN ® |
| ATMOS Chair Professional | ATMOS Chair Professional |
| ATMOS Chair Comfort | ATMOS Chair Comfort |
| ATMOS Chair Doctor | ATMOS Chair Doctor |
Catalogs / Downloads
- Brochure ATMOS S 61 Servant / ATMOS S 61 CORIAN ®
- Brochure The cleaning and care of CORIAN ®
- Flyer CORIAN ® in medical technology
- Declaration of Conformity / Konformitätserklärung Cabinets, Instrument / Schrank, Instrumente ATMOS S 61 CORIAN ® instruments
- Declaration of Conformity / Konformitätserklärung ENT treatment unit / HNO-Diagnose- und Behandlungseinheit
- Declaration of Conformity / Konformitätserklärung Mounting Accessories / Zubehör Gerätepositionierung
- Declaration of Conformity / Konformitätserklärung Storage Accessories / Zubehör Aufbewahrung
- Operating Instructions ATMOS S 61 CORIAN ® Instruments Integral