ECO-X
- Manufacturer
- Ritter
- Category
- Dentistry, Medical clinics
- Application area
- Dentistry
Superior Image Quality Striking contrast and sharpness of images produced by HDX WILL’s image reconstruction technology
Description
ECO-X
Digital Panorama and Cephalometric Imaging
3D Imaging Max 16×10 cm FOV, perfect for capturing dentition, sinus, or TMJ
Bitewings Extraoral bitewing images for better patient comfort
Model Scan Option Model CBCT Scan for STL extraction
PANO with Autofocus 2D panoramic feature with Autofocus for minimized distortion
Cephalometric X-ray (optional) Max 16×10 cm FOV, perfect for capturing dentition, sinus, or TMJ
Superior Image Quality Striking contrast and sharpness of images produced by HDX WILL’s image reconstruction technology
Minimized Metal Artifacts PrecisionMAR (Metal Artifacts Reduction) allows for greater diagnostic accuracy by significantly reducing metal artifact
Low Dose Radiation CBCT radiation exposure lower than standard panoramic scan* – w/AEC & Ultra low dose mode
Wide FOV (Max 16×10cm) Wide FOV gives the flexibility to capture the dentition, TMJ, or sinus
Auto Cephalometric Landmark Tracing* Spend more time with your patients, and less time landmark tracing with WillCeph’s Auto tracing feature. *Available with WillCeph software purchase
• kV Range: 60 kV ~ 90 kV • mA Range: 4 mA ~ 10 mA • Gray Scale: 16 bits / 14 bits • Detector Type: TFT: a-Si (CT), CMOS (Cephalo) • Focal spot: 0.5mm • Scan Time: CBCT : 24 s (Normal) | 8 or 12 s (Low Dose) • Patient position: Standing (Wheelchair accessible)
Dimension (W×D×H): Eco-X: 980 mm × 1225 mm × 2314 mm Dimension (W×D×H): Eco-XS : 1802 mm × 1225 mm × 2314 mm System Weight Eco-X 178 kg System WeightEco-XS 211 kg
Specifications
| kV Range | 60 kV ~ 90 kV |
|---|---|
| mA Range | 4 mA ~ 10 mA |
| Gray Scale | 16 bits / 14 bits |
| Detector Type | TFT: a-Si (CT), CMOS (Cephalo) |
| Focal spot | 0.5mm |
| Scan Time | CBCT : 24 s (Normal) | 8 or 12 s (Low Dose) |
| Patient position | Standing (Wheelchair accessible) |
| Dimension (W×D×H) | Eco-X: 980 mm × 1225 mm × 2314 mm Dimension (W×D×H): Eco-XS : 1802 mm × 1225 mm × 2314 mm System Weight Eco-X 178 kg System WeightEco-XS 211 kg |
| kV Range | 60 kV ~ 90 kV |
| mA Range | 4 mA ~ 10 mA |
| Gray Scale | 16 bits / 14 bits |
| Detector Type | TFT: a-Si (CT), CMOS (Cephalo) |
| Focal spot | 0.5mm |
| Scan Time | CBCT : 24 s (Normal) | 8 or 12 s (Low Dose) |
| Patient position | Standing (Wheelchair accessible) |
| Dimension (W×D×H) | Eco-X: 980 mm × 1225 mm × 2314 mm Dimension (W×D×H): Eco-XS : 1802 mm × 1225 mm × 2314 mm System Weight Eco-X 178 kg System WeightEco-XS 211 kg |
Catalogs / Downloads