MEDAP S VAC

Manufacturer
ATMOS
Category
Medical clinics, Respiratory care and suction
Application area
Respiratory care

Powerful tapping unit for the central gas supply system

Description

MEDAP S VAC Excellent combination of best quality and modern design The different versions of the MEDAP S VAC tapping unit enable silent and extremely powerful aspiration via the terminal unit for vacuum of the central gas supply system. These modern tapping units are extremely lightweight thanks to their impact-resistant ABS plastic housing, and their large, rounded surfaces provide optimum hygienic conditions. A large control valve makes it easy to set the vacuum to the precise level required. Clearly visible ON and OFF buttons on the sides show the unit’s operating status. The MEDAP S VAC is CF-compatible and MR-conditional up to 4.7 teslas. Excellent visual monitoring The large vacuum gauge with a diameter of 63 mm together with large, clear numbers in kPa and mmHg ensure excellent readability — even from a distance — and a safe workflow. Indication-specific labelling Two versions of the MEDAP S VAC are available: one for surgical or bronchial aspiration and one for drainage aspiration. A large, coloured indication label makes it easy to distinguish indications clearly — especially when using multiple tapping units at the same time. MEDAP S VAC B 900 for surgical and bronchial aspiration MEDAP S VAC D 200 for drainage aspiration MR-conditional Made using special materials MR-conditional up to 4.7 teslas ON and OFF buttons as a slide switch The ON and OFF buttons are clearly visible. The markings make it easy to recognise the corresponding setting. FAQ Why does the MEDAP S VAC have a label for specific indications? Two versions of the MEDAP S VAC are available: one for surgical or bronchial aspiration and one for drainage aspiration. Both versions look the same except for the different vacuum gauge scales. In the intensive care unit, a patient may require both bronchial and drainage aspiration. To avoid confusion, special indication labels show the respective indication. What function does the hole have on the back of the MEDAP S VAC D 200? The hole is a safety valve on the patient side that opens at a pressure of 20 kPa and ensures that the maximum vacuum of 20 kPa is not exceeded during drainage. Why is the DIN gas pin on the MEDAP S VAC so long? In some intensive care units, the terminal units are in wall channels. An equipment rail often runs just beneath the terminal units. If an overflow protection device is used below the MEDAP S VAC, it could collide with the equipment rail of the wall channel. Therefore, the length of the DIN gas pin was designed in such a way that the MEDAP S VAC cannot come into conflict with the equipment rail even if an overflow protection device is used. Why can’t the vacuum connection tube to the septic fluid jar be connected directly to the MEDAP S VAC? In accordance with the international standard ISO 10079 for medical suction equipment, the use of a hydrophobic overflow protection device and a bacterial filter is mandatory. The MEDAP S VAC has the same connection as the MEDAP S AIR. That means the same adapter, and therefore the same hydrophobic bacterial and viral filter, can be connected to the MEDAP S VAC as to the MEDAP S AIR.

  • Excellent visual monitoring The large vacuum gauge with a diameter of 63 mm together with large, clear numbers in kPa and mmHg ensure excellent readability — even from a distance — and a safe workflow.
  • Indication-specific labelling Two versions of the MEDAP S VAC are available: one for surgical or bronchial aspiration and one for drainage aspiration. A large, coloured indication label makes it easy to distinguish indications clearly — especially when using multiple tapping units at the same time. MEDAP S VAC B 900 for surgical and bronchial aspiration MEDAP S VAC D 200 for drainage aspiration
  • MR-conditional Made using special materials MR-conditional up to 4.7 teslas
  • ON and OFF buttons as a slide switch The ON and OFF buttons are clearly visible. The markings make it easy to recognise the corresponding setting.

Variants

MEDAP S VAC D 200MEDAP S VAC D 200
MEDAP S VAC B 900MEDAP S VAC B 900
DINDIN
MEDAPMEDAP
BSBS
NFNF
SSSS
Equipment railEquipment rail
Mechanical overflow protectionMechanical overflow protection
Hydrophobic bacterial and viral filterHydrophobic bacterial and viral filter
MEDAP Portable Aspiration UnitMEDAP Portable Aspiration Unit
MEDAP Mobile Aspiration UnitMEDAP Mobile Aspiration Unit
MEDAP Connection TubesMEDAP Connection Tubes

Catalogs / Downloads