RX AC/DC
- Manufacturer
- Ritter
- Category
- Dentistry, Medical clinics
- Application area
- Dentistry
Owandy-RX-AC-DC provide very precise exposure times with guaranteed control thanks to microprocessor controlled timer. Keep your patients safe with HF technology that reduces x-ray doses by eliminating harmful soft rays. Activates automatic exposure time compensation, regardless of any fluctuations in the mains supply. The flexible arm allows the Owandy-RX to be handled effortlessly, with accurate positioning.
Description
RX AC/DC
X-ray generator
Owandy-RX-AC-DC provide very precise exposure times with guaranteed control thanks to microprocessor controlled timer. Keep your patients safe with HF technology that reduces x-ray doses by eliminating harmful soft rays. Activates automatic exposure time compensation, regardless of any fluctuations in the mains supply. The flexible arm allows the Owandy-RX to be handled effortlessly, with accurate positioning.
• Category: Class I, type B (CEI EN60601-1:2007) • Supply voltage: 115/220/230 V – single phase 50/60 Hz (AC); 115/230 V – single phase 50/60 Hz (DC) • Power input: 0,8 kVA (AC); 1,4 kVA (DC) • High voltage: 70 kV (AC); 60 à 70 kV (DC) • Anode current: 8 mA (AC); 4 à 8 mA (DC) • Total filtration: Equivalent to 2 mm Al. à 70 kV • Leakage radiation: < 0,25 mGy/h • Technology: Alternating current (AC); Direct current (DC) • Timer: from 0.08 to 3.2 secs AC); from 0.02 to 3.2 secs (DC) • Head weight: 9 kg (AC); 5,5 kg (DC) • Total weight: 23 kg (AC); 19,5 kg (DC) • Arm extensions: 41 cm / 82,5 cm / 110 cm • Options: Mobile version (AC); Mobile version, Wireless (DC) • Accessories: Long cone (31cm) / Long rectangular cone (31cm) * not available in France, Italy, Spain, Portugal, Turkey, Saudi Arabia, UAE, Egypt, Mexico, Argentina
Specifications
| Category | Class I, type B (CEI EN60601-1:2007) |
|---|---|
| Supply voltage | 115/220/230 V – single phase 50/60 Hz (AC); 115/230 V – single phase 50/60 Hz (DC) |
| Power input | 0,8 kVA (AC); 1,4 kVA (DC) |
| High voltage | 70 kV (AC); 60 à 70 kV (DC) |
| Anode current | 8 mA (AC); 4 à 8 mA (DC) |
| Total filtration | Equivalent to 2 mm Al. à 70 kV |
| Leakage radiation | < 0,25 mGy/h |
| Technology | Alternating current (AC); Direct current (DC) |
| Timer | from 0.08 to 3.2 secs AC); from 0.02 to 3.2 secs (DC) |
| Head weight | 9 kg (AC); 5,5 kg (DC) |
| Total weight | 23 kg (AC); 19,5 kg (DC) |
| Arm extensions | 41 cm / 82,5 cm / 110 cm |
| Options | Mobile version (AC); Mobile version, Wireless (DC) |
| Accessories | Long cone (31cm) / Long rectangular cone (31cm) * not available in France, Italy, Spain, Portugal, Turkey, Saudi Arabia, UAE, Egypt, Mexico, Argentina |
| Category | Class I, type B (CEI EN60601-1:2007) |
| Supply voltage | 115/220/230 V – single phase 50/60 Hz (AC); 115/230 V – single phase 50/60 Hz (DC) |
| Power input | 0,8 kVA (AC); 1,4 kVA (DC) |
| High voltage | 70 kV (AC); 60 à 70 kV (DC) |
| Anode current | 8 mA (AC); 4 à 8 mA (DC) |
| Total filtration | Equivalent to 2 mm Al. à 70 kV |
| Leakage radiation | < 0,25 mGy/h |
| Technology | Alternating current (AC); Direct current (DC) |
| Timer | from 0.08 to 3.2 secs AC); from 0.02 to 3.2 secs (DC) |
| Head weight | 9 kg (AC); 5,5 kg (DC) |
| Total weight | 23 kg (AC); 19,5 kg (DC) |
| Arm extensions | 41 cm / 82,5 cm / 110 cm |
| Options | Mobile version (AC); Mobile version, Wireless (DC) |
| Accessories | Long cone (31cm) / Long rectangular cone (31cm) * not available in France, Italy, Spain, Portugal, Turkey, Saudi Arabia, UAE, Egypt, Mexico, Argentina |
Catalogs / Downloads
Request documentation: info@medicca.eu.